Fluorine Pump Intelligent Dual Cycle Refrigerant System Precision Air Conditioning

Ask Latest Price
Video Channel
Brand Name :Coolent
Model Number :CYA
Certification :ISO/CE
Place of Origin :China
MOQ :1 Unit
Price :3000-20000USD/UNIT
Payment Terms :T/T, L/C
Supply Ability :1000/Month
Delivery Time :15-20 DAYS
Packaging Details :Standard export packaging
Total Capacity :30KW-100kw
Fan Section :Centrifugal EC FAN
Air Flow(㎡/h) :9200-27000
Air Fiter :G4
Compressor :Scroll Compressors
Refrigerant :R410A
Humidifier Inlet Pipe(in) :G1/2"
Condensate Drainage DN(mm) :18
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Product Description

Coolnet fluorine pump series dual-cycle refrigerant system is a high-efficiency and energy-saving precision air conditioner. It provides precise temperature and humidity control for large and medium-sized data rooms.Dual cycle system makes full use of outdoor natural cold sources and uses a set of refrigeration systems to achieve three refrigeration modes, It adopts high-efficiency compressor and EC centrifugal fan to meet the requirements of 24X7 all-weather continuous operation.

Fluorine Pump Intelligent Dual Cycle Refrigerant System  Precision Air Conditioning

Advantages

Fluorine Pump Intelligent Dual Cycle Refrigerant System  Precision Air Conditioning

Natural Cooling Mode of Fluorine Pump

  • Operating Mode Description:The fluorine pump

component operates independently of the pump, The

gaseous refrigerant completely condenses into liquid

in the natural cooling coil, significantly reducing the

energy consumption of the unit on of the unit is

significantly reduced

  • Outdoor Ambient Temperature :≤5℃
  • Applicable Season : Winter

Mixed Refrigeration Mode

  • Operating Mode Description:The fluorine pump

component and compressor operate together,

resulting in a significant improvement in overall

energy efficiency

  • Outdoor Ambient Temperature :>5℃,≤15℃
  • Applicable Season : Spring & Autumn

Compressor Refrigeration Mode

  • Activate the compressor mode to meet the normal

cooling requirements of the computer room.

  • Outdoor Ambient Temperature :>15℃ Applicable
  • Season : Summer