19 Inch Rack-Mounted Online UPS with Component-Level Protection and High Power Density
Product Description
Introducing our state-of-the-art High-Performance Modular UPS with Component-Level Protection and High Power Density. This advanced UPS system represents the pinnacle of power backup technology, providing uninterrupted power supply to critical systems and equipment in various industries. Engineered for reliability, scalability, and efficiency, our UPS solution is designed to meet the diverse needs of modern enterprises. | ![]() |
Product Feature
![]() |
The UPS system is built on a modular architecture, with independent modules for power conversion, control, and battery backup. This modular design enables easy expansion and maintenance, minimizing downtime and reducing operational costs.
Advanced protection mechanisms are implemented at the component level to safeguard against electrical faults, ensuring system integrity and reliability.
Utilizing state-of-the-art power electronics and control algorithms, our UPS system achieves high efficiency, reducing energy waste and operating costs.
Hot-swappable modules facilitate quick and hassle-free maintenance and upgrades without interrupting power supply to critical loads, further enhancing system reliability and uptime.
Integrated monitoring software allows for real-time monitoring, remote diagnostics, and proactive maintenance, empowering administrators to effectively manage the UPS system from anywhere.
Intelligent cooling systems adjust fan speeds based on load and ambient conditions, ensuring optimal performance and reliability while minimizing energy consumption. |
Product Advantages
Enhanced Protection: Unlike conventional UPS systems, our solution incorporates component-level protection mechanisms, mitigating the impact of electrical faults and ensuring continuous operation even in the face of component failures.
High Power Density: Despite its compact footprint, our UPS system boasts high power density, making it suitable for installations with limited space constraints. This high power density allows for maximum space utilization without compromising performance.
Scalability and Flexibility: Featuring a modular design, our UPS system offers scalability and flexibility to adapt to evolving power requirements. Administrators can easily expand the system to accommodate growing loads, ensuring seamless scalability for businesses of all sizes.
Energy Efficiency: With advanced power electronics and control algorithms, our UPS solution optimizes energy efficiency, reducing overall power consumption and operating costs. This energy-efficient design not only lowers utility bills but also minimizes the environmental impact.
Intelligent Monitoring and Management: Equipped with comprehensive monitoring and management capabilities, our UPS system enables administrators to monitor system performance in real-time, diagnose issues remotely, and implement proactive maintenance measures. This ensures maximum uptime and reliability for critical operations. | ![]() |
Data Sheet
Model CNM | 020/10 | 030/15 | 040/20 | 040/10 | 045/15 | 060/15 | 080/20 | 090/15 | 120/20 |
Rate Power | 20KVA/20KW | 30KVA/30KW | 40KVA/40KW | 40KVA/40KW | 45KVA/45KW | 60KVA/60KW | 80KVA/80KW | 90KVA/90KW | 120KVA/120KW |
Main input | |||||||||
Input | 3P5W(3P+N+PE) | ||||||||
Rate Voltage | 380/400/415VAC(L-L);220/230/240VAC(L-N) | ||||||||
Rate Freq | 50/60Hz | ||||||||
Input PF | >0.99 | ||||||||
Current Distortion | THDi<3%(100%Linear load) | ||||||||
Voltage Range | 304-478VAC(L-L)full load;304-228VAC(L-L)power derate from 100%to 75% | ||||||||
Freg.Range | 40-70Hz | ||||||||
Battery | |||||||||
Rate voltage | ±240VDC(adjustable for 32-44 sections) | ||||||||
Charging Capacity | 20%*Pout | ||||||||
Charging Accuracy | ±1% | ||||||||
Bypass | |||||||||
Rate Voltage | 380/400/415VAC(L-L);220/230/240VAC(L-N) | ||||||||
Voltage Range | Range:-40%-+25%,Settable,default-20%~+15% | ||||||||
Overload | 110%,long time operation;110%<load<125%,5 mins 125%<load<150%,1min;>150%,1second | ||||||||
Inverter | |||||||||
Rate Voltage | 380/400/415VAC(L-L);220/230/240VAC(L-N) | ||||||||
Rate Freq | 50/60Hz | ||||||||
Output PF | 1 | ||||||||
Voltage Accuracy | ±1.0% | ||||||||
load Response | <5%(20%-80%-20%step load) | ||||||||
Recovery Time | <20ms(0%-100%-0%step load) | ||||||||
Output THDu | <1%(linear load),<5%(non-linear load according to IEC 62040-3) | ||||||||
Overload | 110%,1 hour;125%,10 mins;150%,1min;>150%,200ms | ||||||||
Frequency Accuracy | 0.1% | ||||||||
Synchronize Window | Settable,±0.5Hz-±5Hz,default±3Hz | ||||||||
Slew Rate | Settable,0.5Hz/S-3Hz/S,default 0.5Hz/S | ||||||||
Phase Accuracy | 120°±0.5° | ||||||||
System | |||||||||
Efficiency | Normal Mode≥96%;Battery Mode≥96% | ||||||||
Display | LED+7inch touch LCD | ||||||||
Certification-Safety | IEC62040-1,IEC60950-1 | ||||||||
Certification-EMS | IEC62040-2;IEC61000-4-2(ESD);IEC61000-4-3(RS);IEC61000-4-4(EFT);IEC61000-4-5(Surge) | ||||||||
IP Degree | IP20 | ||||||||
Configuration | USB,RS232,RS485,Dry contact,Cold start | ||||||||
Option | SNMP card,AS400 card,Parallel kit,LBS,Air filter,Bottom entry kit,Wheels kit | ||||||||
Environment | 0-40℃(operation);-25~70(storage);0-95%(Humidity,non-condensing) | ||||||||
Noise(dB)(1meter) | 65dB @100%load,62dB @45%load | ||||||||
Dimension | |||||||||
Cabinet(W*D*H)mm | 482*700*396(9U, wheels not included) | 482*700*662(15U, wheels not included) | 482*700*840(19U, wheels not included) | ||||||
Module(W*D*H)mm | 440*555*85(2U) |