Add to Cart
PDU provides safe power distribution and can be installed horizontally or vertically
Production
Intelligent monitoring PDUs are complete and versatile, and can meet the needs of high-end server rooms and data centre software intelligent power distribution and environmental monitoring systems. Intelligent PDUs can monitor both current, voltage, electrical energy, power factor, carbon emissions, fuse status, surge effectiveness and other data. It can also monitor temperature, humidity, flooding, access control, human body sensing, etc. through sensors. Remote control via CP/IP, SNMP and other protocols Power on/off, sequential power on/off, threshold alarm management, authority management, a good helper for power management. Intelligent solutions allow users to Enable power distribution to be embedded into the server room dynamic loop management system. More precise and effective monitoring of energy consumption, equipment operation control and monitoring of the server room environment. | ![]() |
Functions of Intelligent PDU
![]() | 1, Energy Monitoring Function It can provide abundant functions such as energy usage, efficiency and environmental monitoring in data center etc. The input voltage and current of each circuit can be measured by intelligent PDU, and the usage of power can be calculated in watts or kilowatts. The total energy usage can be calculated, from which the operators of data center decide whether they need to add PDU or not. 2, Environmental Monitoring Function Environmental monitoring and management can be carried out through the existing data center LAN by new generation of intelligent PDU. Intelligent PDU integrates multiple temperature and humidity/moisture sensors. Intelligent PDU can track environmental factors and issue warning timely. In addition, the administrator can also compare the environment data with the energy consumption data to confirm the energy consumption of the server, and inspect actual effect of the temperature control measures for inner rack. 3, PDU Access and Network Function Intelligent PDU can be connected through the LAN form, and be flexibly managed through a Web browser or command line interface (CLI).lt makes the administrator easily access the data, for real-time monitoring. |
Software Function
| ![]() |
Parameter
PDU |
Parameters | |
input | Input type | AC single phase, AC three phase,-48VDC,240VDC,336VDC |
Input mode | Transparent open type junction box,power cord, cable, industrial connector, socket etc. | |
Input voltage range | 100-277VAC/312VAC-418VAC/11VDC-240VDC/-43VDC- -56VDC | |
AC input frequency | 50/60Hz | |
total load current | MAX 63A | |
Output | Storage temperature | -40 - +70 |
Relative humidity | 5-95% (No condensation) | |
Atmospheric pressure | 70kPa - 106kPa | |
Working altitude | No more than 4000M | |
Environmental | Working temperature | -10 - +75 |
Storage temperature | -40 - +80 | |
Relative humidity | 5-95% (No condensation) | |
Working altitude | No more than 4000M | |
IP rating | IP20 | |
Protection | input protection module | Circuit breaker, lightning protection, leakage protector, temperature insepction module (optional) |
Output protection module | Circuit breaker, fuse box, fuse(optional) |
Certifications
Case