Row Based Cool Row Precision Air Conditioning Units For Server Room

Ask Latest Price
Video Channel
Brand Name :COOLNET
Model Number :XR023A, XR040A
Certification :CE,ISO
Place of Origin :CHINA
MOQ :1set
Price :1800-30000USD
Payment Terms :T/T, L/C
Supply Ability :300 PCS PER MONTG
Delivery Time :20-35working days
Packaging Details :Packed in plywooden case, standard export package
Name :In-Row Air Conditioning Units
Mounting :Floor Standing
Cooling capacity :20-40KW
Voltage :380/400 VAC,230 VAC,220V
Fan type :Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan
Airflow :2000~50000 m3/h
Refrigerant :R410A/ R407C
Application :Data Center, IT room , Computer room, Server room
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Row Based Cool Row Precision Airconditioning Units For Server Room

Row Based Cool Row Precision Air Conditioning Unit For Server Room

Product Introduction

In-row air conditioners are also called in-row air cooling units, or in-row refrigeration units. They are precision refrigeration systems specifically designed for high-heat-density racks. They are placed directly between the rows of server cabinets and dissipate heat directly near the heat source. Generally, the compressors of air-cooled in-row airconditioning units use variable-capacity digital scroll compressors, and the fans use EC fans. The whole machine can adjust the cooling capacity output according to the heat load in the channel. In-row air cooling units are widely used in places, such as condition containerized data centers, various modular data centers, data centers with low PUE requirements, local hot spots in computer rooms, high heat density areas in medium and large computer rooms, and computer rooms Data centers with tight area, etc.

Applications

Biochemical culture room

Power substation and substation

Hospital, operating room, laboratory

Medium and large computer rooms and data centers

Satellite ground station, program-controlled exchange room

Museums, money-printing factories, banks, wine cellars

Electronics manufacturing, biopharmaceutical, food manufacturing

Technical specifications (indoor unit)

Row Based Cool Row Precision Air Conditioning Units For Server Room

Row Based Cool Row Precision Air Conditioning Units For Server Room

Features

Row Based Cool Row Precision Air Conditioning Units For Server Room
  • Design of refrigeration system with large air volume, small enthalpy difference, high sensible heat ratio and high energy efficiency

  • Intelligent controller: it can automatically adjust the cooling capacity and air output with the change of heat load

  • Flexible cooling capacity design: automatically adjust the cooling capacity according to the heat change of room equipment

  • High ventilation rate: the front and rear mesh doors are designed, and the through rate is up to 80%, meeting the heat dissipation requirements of high thermal density

  • Ultrasonic humidification: the first case in the industry, with energy saving, even humidification, high humidification intensity and better humidification effect.

  • Electronic expansion valve: high accuracy, wide adjustment range, fast reaction speed, improve the energy efficiency ratio of the system

  • Variable capacity scroll compressor: variable frequency, high energy efficiency, variable capacity cooling output

  • Rapid dehumidification design: Aluminum alloy fin, fast heating, over temperature protection, ensure dehumidification and reduce reheat power consumption

  • Double EC fan: redundant design, the air volume is automatically adjusted according to the room load, saving more than 30% energy

  • Mounted close to the rack and closer to the heat source, it can continuously monitor the change of heat load and immediately carry out energy-efficient cooling

  • Front supply air and back return air design, higher refrigeration efficiency and more energy saving

  • Modular air guide system: flexible air flow organization, adjustable left and right air supply on site, suitable for various practical application scenarios

  • The outdoor fan adopts stepless full speed control to ensure healthier system operation, more energy saving and lower noise

Technical Parameter

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

Certificates

Row Based Cool Row Precision Air Conditioning Units For Server Room

Factory Details

Row Based Cool Row Precision Air Conditioning Units For Server Room

Packing & Delivery

Row Based Cool Row Precision Air Conditioning Units For Server Room

Case

Row Based Cool Row Precision Air Conditioning Units For Server Room

Inquiry Cart 0