Row Type Air Conditioning Specially Designed For Telecom Room

Ask Latest Price
Video Channel
Brand Name :Coolent
Model Number :CYAS40D/U
Certification :ISO/CE
Place of Origin :China
MOQ :1Unit
Price :USD3500-10000Unit
Payment Terms :T/T, L/C
Supply Ability :1000Unit/Month
Delivery Time :20-35Days
Packaging Details :Packed in plywooden case, standard export package
cooling capacity :60KW
Condition :New
Type :Air cooled unit
After-sales service provided :Engineers available to service machinery overseas
Operating voltage :380/400 VAC,230 VAC,220V
Refrigerant :R22(R407C/R410A)
more
Contact Now

Add to Cart

Find Similar Videos
White Precise Computer Room Ac Units For Small Power Rooms And Substations 00:23
White Precise Computer Room Ac Units For Small Power Rooms And Substations
View Product Description

Specially Designed For Telecom Room Of In Row Type Air Conditioning

Product Introduction

COOLNET In-row Precision AC is an in-row air conditioner tailored for the specific cooling requirements of high-density cabinets, solving the user's local hot spot problem and suitable for a variety of different user installation conditions and cooling density requirements. The advanced DC inverter refrigeration system is adopted, and the mainstream environmentally friendly refrigerant R410A is used. The frequency adjustment is carried out in real time to ensure the stability of the computer room environment.

Advantage

  • Proximal refrigeration:refrigeration near the heat source, combined with the design of hot and cold channels, further optimize the indoor air distribution, reduce the overall PUE value of the room, and improve the refrigeration efficiency.
  • High energy efficiency ratio: high return air temperature and high heat output air temperature matching degree is high, making the unit energy efficiency ratio is very good, low consumption, energy saving, low operating cost.
  • High reliability: super long life design, 24 hours and 365 days uninterrupted operation, the average design life is about 10 years.
  • Using DC frequency conversion compressor, dynamic refrigeration, high efficiency, low consumption, high adaptability; An EC centrifugal fan with N+1 redundancy is configured to automatically adjust the air supply volume according to the equipment room load.
  • The standard rack size is the same as the cabinet appearance. It is beautiful and easy to expand capacity.

Row Type Air Conditioning Specially Designed For Telecom Room
Row Type Air Conditioning Specially Designed For Telecom Room

Application

In row air conditioners are specially designed for modern modular data centers, such as high-thermal density data centers, various modular data centers, data centers with low PUE requirements, local hot spots in the equipment room, high-thermal density areas in medium-large equipment rooms, and data centers with limited equipment room area.

Technical Features

High Efficiency-DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

High Efficiency-Electronic Expansion Valve

Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving;

Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;

Fast response speed, realizing precise refrigeration;

High Efficiency-Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design

Row Type Air Conditioning Specially Designed For Telecom Room

Technica Parameter

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

Factory Details

Row Type Air Conditioning Specially Designed For Telecom Room
Delivery & Packing
Row Type Air Conditioning Specially Designed For Telecom Room

Inquiry Cart 0
You May Like
Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers
Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers
2000m3/H In Row Air Conditioning Unit , Precision Air Conditioner For Server Room
2000m3/H In Row Air Conditioning Unit , Precision Air Conditioner For Server Room
Row Based PACU Air Conditioning Unit Place Close To The Heat Source
Row Based PACU Air Conditioning Unit Place Close To The Heat Source
In Row Air Conditioning Unit  Data Center Precision Air Conditioner
In Row Air Conditioning Unit Data Center Precision Air Conditioner
Data Center Rack 23.5KW Precision In Row Cooling Unit
Data Center Rack 23.5KW Precision In Row Cooling Unit
EC Fan In Row Air Conditioning Unit , Server Room Air Conditioning Unit
EC Fan In Row Air Conditioning Unit , Server Room Air Conditioning Unit
Computer Room Server Rack Cooling Unit Row-Based Cooling
Computer Room Server Rack Cooling Unit Row-Based Cooling
HVAC Data Centre R410A In Row Air Conditioning Unit
HVAC Data Centre R410A In Row Air Conditioning Unit
400VAC Data Center Precision Air Conditioner Closer To Server Rack
400VAC Data Center Precision Air Conditioner Closer To Server Rack
300mm Air Cooled In Row Air Conditioning Unit For Server Room
300mm Air Cooled In Row Air Conditioning Unit For Server Room
25kW In Row Air Conditioning Unit , IT Room Air Conditioner Floor Standing
25kW In Row Air Conditioning Unit , IT Room Air Conditioner Floor Standing
380v Black InRow Air Cooling Unit For Modularized Data Centers
380v Black InRow Air Cooling Unit For Modularized Data Centers
R410A Inrow Cooling Unit For Modular Data Center  Cooling
R410A Inrow Cooling Unit For Modular Data Center Cooling
High Density Cooling In Row Air Conditioning Unit, APC Precision Air Conditioning
High Density Cooling In Row Air Conditioning Unit, APC Precision Air Conditioning
In Row Cooling Data Room Air Conditioning Unit 40kW
In Row Cooling Data Room Air Conditioning Unit 40kW
Send your message to this supplier
*From:
*To:

Hefei Coolnet power Co., ltd

*Subject:
*Message:
Characters Remaining : (0/3000)
Contact Now