15KW In Row Precision Air Conditioners For Server Rooms

Ask Latest Price
Video Channel
Brand Name :COOLNET
Model Number :CR012 CR040
Certification :CE,ISO
Place of Origin :CHINA
MOQ :1set
Price :1800-30000USD
Payment Terms :T/T, L/C
Supply Ability :300 PCS PER MONTG
Delivery Time :10-25 working days
Packaging Details :Packed in plywooden case, standard export package
Name :In-Row Precision Air Cooling Unit
Cooling capacity :12.5-15KW
Condition :New
Mounting :Floor Standing Racks
Product Type :Row Based Precision Air Conditioning Unit
Operating voltage :380/400 VAC,230 VAC,220V
Airflow :2000~10000 m3/h
Warranty :1 Year(12 month with no artificial damage)
Refrigerant :R410A/ R407C
Application :Data Center, Computer room, Server rooms
Color :Black/Grey/Blue/Other Colors
Fan type :Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan
Power :3N-380V-50Hz,220v/50hz/60hz
Voltage :380v/220v,220V/380V,380V/415V
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

15KW In-Row Precision Air Conditioners For High Heat Density Places In Server Rooms

Product Introduction

In-row Air Conditioning Precision cooling system designed for high heat density racks. They are placed directly between rows of server cabinets for cooling. Generally, the compressor of the air-cooled tandem air-conditioning unit adopts a variable-capacity digital scroll compressor, and the fan adopts an EC fan. The whole machine can adjust the cooling output according to the heat load in the channel. The determinant air-cooled unit is widely used in containerized data centers, various modular data centers, data centers with low PUE requirements, local hot spots in computer rooms, and high heat density areas in medium and large computer rooms. Computer room, data center with small space, etc.

Features & Benefits

15KW In Row Precision Air Conditioners For Server Rooms

15KW In Row Precision Air Conditioners For Server Rooms

Air Supply Method

15KW In Row Precision Air Conditioners For Server Rooms

Advantages 15KW In Row Precision Air Conditioners For Server Rooms

Energy Efficiency

Inverter compressor, EC fan and electronic expansion valve are standard configurations for DXA series

Air is directly drawn from the hot aisle, allowing the unit to take advantage of higher heat transfer efficiency due to higher Delta T.

Cold aisle/Hot ailse containment avoids mixing of cold and hot air

High Flexibility

Air-cooled or chilled water-cooled cooling scheme.

Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.

High Reliability & Serviceability

24*7 uninterruptible operation design.

Multiple units in data centers, the total cooling capacity will not lower too much until the failed unit can be repaired.

Intelligent Control System

Highest protection against downtime, equipment damage and excess wear and tear.

Touched screen interface offers the full visibility.

Structure & Components

High Efficiency-DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

High Efficiency-Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

15KW In Row Precision Air Conditioners For Server Rooms
15KW In Row Precision Air Conditioners For Server Rooms

Technical Parameter

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3