Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Ask Latest Price
Video Channel
Brand Name :COOLNET
Model Number :XR012A, XR040A
Certification :CE,ISO
Place of Origin :CHINA
MOQ :1set
Price :1800-30000USD
Payment Terms :T/T, L/C
Supply Ability :300 PCS PER MONTG
Delivery Time :10-25 working days
Packaging Details :Packed in plywooden case, standard export package
Cooling capacity :12kw- 40kw
Condition :Brand New
Mounting :Floor Standing Units
Type :In-Row Air Cooling Unit
Operating voltage :380/400 VAC,230 VAC,220V
Warranty :1 Year(12 month )
Product name :Precision Air Conditioning Units
Refrigerant :R22(R407C/R410A)
Application :Data Center, IT room , Computer room, Data Center Cold/hot aisle
Color :Black/Grey/White/Other custom colors
Fan type :EC fan
Power :3N-380V-50Hz,220v/50hz/60hz
Airflow :2000~40000 m3/h
Power Supply :380v/220v,220V/380V,380V/415V
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Precise Heat Dissipation In-Row Air Cooling Units With Large Volume For Data Centers

Product Introduction

The determinant air conditioner is a cooling device arranged in the cabinet rack and installed side by side with the server cabinet. When adjusting the temperature of the entire internal space of the computer room, the traditional air conditioner is generally far away from the heat source, the effect is uneven, and the energy consumption is large. The biggest feature of the in-line air conditioner is that it can be close to the heat source and directly dissipate the heat of the heat source. Its heat dissipation efficiency is higher, which is more conducive to energy saving. Therefore, the use of determinant air conditioners for heat dissipation in computer room cabinets has been more and more widely used.

Feature & Benefits

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Applicatinon Range

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers
  • Mobile base station
  • Outdoor rooms
  • Satellite ground station
  • Paging machine room
  • Network management center
  • Small computer room
  • Small laboratory
  • Wine cellar

Structure & Components

DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design

Electronic Expansion Valve

Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving;

Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Technical Parameter

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

Certificates

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Factory Details

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Packing and Delivery

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Cases

Precise Heat Dissipation In Row Cooling Unit Large Volume For Data Centers

Inquiry Cart 0