Small Data Center Cabinet With Precision Cooling System And Power System For Server Rooms
Product Introduction
The integrated cabinet deeply integrates data center infrastructure products, including multiple subsystems such as UPS, power distribution, refrigeration, cabinets, and fire protection. Through the monitoring system, the entire system is managed as a whole, simplifying the design and construction process.
The reliable UPS power distribution system continuously escorts the IT equipment. At the same time, it is equipped with a precision refrigeration system to ensure the operating environment of the IT equipment. It is equipped with a dynamic ring monitoring system to monitor the working status of the equipment in real time. The integrated cabinet adopts a fully sealed design and can be used in a variety of harsh indoor environments without the need to set up a separate computer room.
Benefits | ![]() |
Advantages
![]() | 1. Lower cost The minimum floor area is only 0.7m2, the closed design, strong environmental adaptability, no need for decoration, flooring and other supporting projects, effectively reducing CAPEX, fully enclosed refrigeration improves the energy efficiency of the whole machine, reduces OPEX, and significantly reduces the total cost of ownership (TCO).
2. Better management The one-stop after-sales service can deal with various equipment failures in a timely manner, saving time and worry; the standard dynamic monitoring system can be monitored and managed locally and remotely, and multiple outlets can be connected to the upper management platform for unified supervision and diversified support.
3. Integration The integrated cabinet integrates multiple systems such as UPS power supply, power distribution, refrigeration, access control, cabinets, lighting, fire protection, dynamic environment monitoring, and emergency ventilation. Design, Procurement, Construction Process.
4. More time-saving The productized design enables the IC series rack-type smart data center to be installed and delivered on site within one day, which is more than 2 times faster than the traditional construction mode.
|
Application
| ![]() |
Technical Parameter
Model | EC08 | EC12 | EC20 | ERx |
Power | 3KVA | 3-6KVA | 6-30KVA | |
Number of cabinets | 0.8m high cabinet, available space 8U | 1.2m high cabinet, available space 16U | Standard 42U cabinet, free space 30U | 2-10 standard 42U glass door cabinets |
Enclosed cabinet | Glass door, IP5X, full cold and hot channel sealing | |||
Power supply | 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection | 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection | 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection | |
Refrigeration | Unique air duct design, without air conditioner and outdoor unit | Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | |
Monitor | 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display | 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring | 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring |