Server Room Cooling Units For Precise Experiment Rooms

Ask Latest Price
Video Channel
Brand Name :Coolnet
Model Number :CYA,M08,M012,M20
Certification :CE/ISO9001
Place of Origin :China
MOQ :1
Payment Terms :T/T
Delivery Time :4W
Packaging Details :WOODED
Cooling capacity :10-23kw
Condition :Brand New
Mounting :Floor Standing Units
Type :Precision air conditioning unit(air cooled/chilled water)
After-sales service :Engineers available to service machinery overseas
Voltage :380/400 VAC,230 VAC,220V
Refrigerant :R22(R407C/R410A)
Application areas :Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity
Airflow :2000~10000 m3/h
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Server Room Cooling Units For Precise Experiment Rooms To Provide Fixed Temperature

Product Introduction

Cool-smart series is a series of unit air conditioners developed for small and medium-sized communication data centers. It can control the temperature and humidity of the computer room, and has a variety of cooling capacity models, which can be flexibly selected according to the actual situation of the client room. Each air-cooled Cool-smart series system consists of an indoor unit and an outdoor unit.

Features

High reliability

  • Provide Constant temperature & humidity, cleanness precision environment to ensure the main equipment in good running condition
  • 24-hour running design guarantee main equipment operation safety
  • All units had passed a severe running test before delivery, which can ensure units’ high reliability.

High energy efficiency

  • SHR (sensible heat ratio) is larger than 90%.
  • Compressor EER is larger than 3.1
  • Optimal and high efficiency compressor and fan in CRAC industry.
  • Maximum evaporator in CRAC industry ensures the highest heat exchange efficiency.
  • Optimal CFD air duct design: minimum air duct resistance & minimumfan power
  • Inverter IDU: high efficiency & long working life
  • Advanced control logic: avoid competitive running and output cooling capacity according to actual cooling capacity demand.

Easy maintenance

  • Front panel maintenance: all maintenance operation can be finished
  • from the front panel
  • Air filter with metal frame: cleanable repeatedly with low maintenance cost.
  • Auto-clean function: lower maintenance work
  • Metal frame with marine protection grade: durable and less maintenance work.
  • All metal fans of ODU & IDU: durable & high end
  • Remote control: convenient management & maintenance
Server Room Cooling Units For Precise Experiment Rooms

Scope of Application

  • Small-Medium size computer room
  • Communication base
  • Rail road, Army, Broadcast base
  • Power room, substation
  • Monitoring room, Power distribution room, Battery room
  • High precision lab, Test room, Inspection room, Measuring room
  • Industrial control room, Precision workshop
  • Archives,Store room, Museum, Wine cellar

Server Room Cooling Units For Precise Experiment Rooms

Product Specification

Model M04 M06 M08 M13 M16 M20
Power Supply 220V1Ph-50Hz 380V3Ph-50Hz
Air discharge Up Front/Down
Technical Data Sheet
AC Fan Total cooling capacity-KW 4.2 6.4 7.5 12.5 16.8 20.2
Sensible cooling capacity-KW 3.9 5.8 6.9 11.3 15.3 18.3
Unit FLA-A(heating, humidifying type) 20.0 25.0 16.8 22.0 23.5 28.6
Compressor Quantity 1
Fan Quantity 1
Air Volume-m3/h 1600 1900 2300 3600 5100 6500
Heater Capacity-KW 3.0 3.0 6.0 6.0 6.0 6.0
Humidification-kg/h 3 3 3 3 6 6
Power of humidifier-KW 2.3 2.3 2.3 2.3 4.5 4.5
Outdoor Condenser
Model SCA020 SCA020 SCA030 SCA030 SCA050 SCA050
Standard unit operating temperature range-℃ -15-45℃
Low Temperature Components Operating Temperature Range-℃ -40-45℃

Certificates

Server Room Cooling Units For Precise Experiment Rooms

Factory Details

Server Room Cooling Units For Precise Experiment Rooms

Delivery & Packing

Server Room Cooling Units For Precise Experiment Rooms

Case

Server Room Cooling Units For Precise Experiment Rooms

Inquiry Cart 0