Hefei Coolnet power Co., ltd

Hefei Coolnet power Co., ltd

Manufacturer from China
Verified Supplier
6 Years
Home / Products / In Row Air Conditioning Unit /

In Row Air Conditioners For Data Centers And Network Management Centers

Contact Now
Hefei Coolnet power Co., ltd
Visit Website
City:hefei
Province/State:anhui
Country/Region:china
Contact Person:Janet Si
Contact Now

In Row Air Conditioners For Data Centers And Network Management Centers

Ask Latest Price
Video Channel
Brand Name :Coolent
Model Number :XR023-040
Certification :ISO/CE
Place of Origin :China
MOQ :1
Price :to be Negotiated
Payment Terms :T/T
Supply Ability :1000/Month
Delivery Time :4W
Packaging Details :WOODEN
Capacity :20-40KW
Mounting :Floor Standing
Application :Modularized data center, High heat density data center, Container data center
Refrigerant :R410A/R407C
Product Condition :New
Product Type :In Row Air Cooling Units
After-sales service provided :Engineers available to service machinery overseas
Power Supply :380/400 VAC,230 VAC,220V , 50/60HZ
Warranty :1 Year(12months)
Product Name :Row Based Cooling Unit
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

In-Row Precision Air Conditioners For Data Centers And Network Management Centers

Product Introduction

Inrow cooling precisely cools and conditions air in close proximity and is targeted cooling at the banks of server cabinets that fill the data center. They can be installed on the floor or suspended from overhead making them closer to the actual rack. This setup offers both capacity and efficiency gains. Neither cool air nor warm exhaust air has far to travel, allowing the units to dissipate high heat loads quicker and allows a more scalable approach to cooling your data center.

Application

  • Single rack with power larger than 3kW
  • High heat density computer room
  • Modular DC
  • Container type DC
  • DC with low PUE
  • Hot spot reconstruction
In Row Air Conditioners For Data Centers And Network Management Centers

Air Supply Method

In Row Air Conditioners For Data Centers And Network Management Centers In Row Air Conditioners For Data Centers And Network Management Centers

Features

In Row Air Conditioners For Data Centers And Network Management Centers

Energy Efficiency

Inverter compressor, EC fan and electronic expansion valve are standard configurations for DXA series

Air is directly drawn from the hot aisle, allowing the unit to take advantage of higher heat transfer efficiency due to higher Delta T.

Cold aisle/Hot ailse containment avoids mixing of cold and hot air

High Flexibility

Air-cooled or chilled water-cooled cooling scheme.

Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.

High Reliability & Serviceability

24*7 uninterruptible operation design.

Multiple units in data centers, the total cooling capacity will not lower too much until the failed unit can be repaired.

Optional Features

Electrical heater and humidifier

Condensate pump

Floor water leakage alarm

ATS

Intelligent Control System

Highest protection against downtime, equipment damage and excess wear and tear.

Touched screen interface offers the full visibility.

AIRSYS NetOne Monitoring & Control for multiple units teamwork. integrated the latest technology of AI, ML and IoT to provide the monitoring and reliability for a more efficient operation of the cooling system.

Technical Parameter

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

Certificates

In Row Air Conditioners For Data Centers And Network Management Centers

Factory Details

In Row Air Conditioners For Data Centers And Network Management Centers

Packing & Delivery

In Row Air Conditioners For Data Centers And Network Management Centers

Cases

In Row Air Conditioners For Data Centers And Network Management Centers

Inquiry Cart 0