Hefei Coolnet power Co., ltd

Hefei Coolnet power Co., ltd

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Precision Air Conditioning Units /

Precise AC Units 100-120kW Providing Constant Temperature In Data Centers

Contact Now
Hefei Coolnet power Co., ltd
Visit Website
City:hefei
Province/State:anhui
Country/Region:china
Contact Person:Janet Si
Contact Now

Precise AC Units 100-120kW Providing Constant Temperature In Data Centers

Ask Latest Price
Video Channel
Brand Name :Coolnet
Model Number :CYA T100
Certification :CE/ISO9001
Place of Origin :China
MOQ :1
Payment Terms :T/T
Delivery Time :4W
Packaging Details :WOODED
Cooling Capacity :102-120kW
Product Mounting :Floor Standing
Type :Air Cooled Unit/Water Cooled Units
Compressor :Emerson/Danfoss Scroll Compressor
Warranty :1 Year
Product Name :Precision Air Conditioning Units
Refrigerant :R22(R407C/R410A)
Application :Computer Room,Printing factory,Industrial workshop
Fan type :Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan
Power :3N-380V-50Hz,220v/50hz/60hz
Airflow :>24200 m3/h
Color :Black,Grey,White
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Precise AC Units 100-120kW Providing Constant Temperature And Humidity In Data Centers

Products Introduction

Coolnet PAC units are designed to "provide a constant temperature and humidity specific operating environment for IT equipment and other precision devices." This is a high-precision air conditioner specially designed for computer rooms. In order to ensure good heat dissipation of computers or server chips, application scenarios include computer rooms, laboratories, large medical equipment rooms and other high-precision fields. Its service objects are related equipment that can keep the computer room running continuously: such as IT equipment, power distribution system, power supply equipment, etc. The precision air conditioner has a "constant temperature and humidity" function, and the temperature difference range can be controlled at 0.1 degrees Celsius or even higher. Therefore, precision air conditioners pay more attention to the design of precise control of temperature and humidity in the computer room and timely control of cleanliness.

Benefits

Precise AC Units 100-120kW Providing Constant Temperature In Data Centers

Precise AC Units 100-120kW Providing Constant Temperature In Data Centers

Technical Features

High reliability

  • 24 hours operation design can guarantee the main equipment safe operation.
  • Strictly tested before delivery
  • Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition.

High energy efficiency

  • Sensible heat ratio is up to 91%,chilled water and Compressor EER>3.1
  • Cooled unit’s cooling energy efficiency is larger than 25.
  • The optimal and high efficiency compressor and fans.
  • Longer working life and more efficient frequency design on ODU
  • Effectively avoid competitive running and dynamic cooling capacity output according to actual cooling demand.
  • “W/M” type evaporator with super large heat exchange area.
  • Independent air duct design can reduce air resistance significantly and minimize fans power.

Easy maintenance

  • Front panel maintenance: All maintenance work can be operated from front panel.
  • Air filter with metal frame: Cleanable repeatedly, low maintenance cost
  • Self-cleaning humidifier: lower maintenance work
  • Modular design with least spare parts
  • Pressure difference monitoring for air filters can detect whether
  • air filters was blocked or not.

Multiple types

  • Capacity range: air cooled type(5kW~120kW),Water cooled type(5-120KW),chilled water cooled type(30kW~200kW).
  • Cooling mode: air cooled, water cooled, glycol cooled, chilled water cooled(with single/dual coil), air cooled & chilled water cooled, air cooled & free cooling, Freon pump free cooling.
  • Air supplying modes:cap tuyere mode, air duct mode, floorboard mode.
  • Refrigerant types: R410A, R407C, R22.
  • Ambient air temperature rang:standard range(-20℃~50℃),low temperature range(-40℃~50℃).
Precise AC Units 100-120kW Providing Constant Temperature In Data Centers

Applications

Precise AC Units 100-120kW Providing Constant Temperature In Data Centers
  • IDC, Computer room
  • Network equipment room, Server room,communication equipment room
  • Monitoring room, Power distribution room and battery room
  • High precision lab, Test room, Inspection room, Measuring room
  • Industrial control room, High precision workshop
  • Archive, Storage room, Museum, Wine cellar

Technical Parameters

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model 2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

Certificates

Precise AC Units 100-120kW Providing Constant Temperature In Data Centers

Factory Details

Precise AC Units 100-120kW Providing Constant Temperature In Data Centers

Packing & Delivery

Precise AC Units 100-120kW Providing Constant Temperature In Data Centers

Case

Precise AC Units 100-120kW Providing Constant Temperature In Data Centers

Inquiry Cart 0