Precision Computer Room AC Units 10-15kW For Small Monitoring Room

Ask Latest Price
Video Channel
Brand Name :Coolnet
Model Number :CYA,M10,M13,M15
Certification :CE/ISO9001
Place of Origin :China
MOQ :1
Payment Terms :T/T
Delivery Time :4W
Packaging Details :WOODED
Name :Precision Computer Room AC Units
Cooling capacity :10-15kW
Condition :Brand New
Mounting :Floor Standing
Type :PAC unit(chilled water) 3ton 5ton 10ton
After-sales Service :Engineers available to service machinery overseas
Operating voltage :380/400 VAC,230 VAC,220V
Precision Air Conditioning :R22(R407C)
Application :Computer Room/Printing factory/supermarket/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity
Airflow :3500~5000m3/h
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Precision Computer Room AC Units 10-15kW For Small Monitoring Room And Power Room

Product Introduction

Cooling capacity range:10-15kW

Types:Cooling, Cooling & electrical heating, Constant temperature & humidity.

Cooling modes:Air cooled, Freon pump, Water cooled & glycol cooled.

Air supply modes:Cap tuyere supply, Air duct supply, Floorboard supply, etc.

Refrigerant types:R22, R407C, R410A

Ambient air temperature: Standard type(-20℃~50℃), Low temperature type(-40℃~50℃)

Advantages

  • Large air volume, small enthalpy difference, high sensible heat ratio
  • RS485 communication protocol interface
  • Precision temperature control in the computer room
  • Self-start function after power failure
  • Low enthalpy difference, no condensation on the rack
Precision Computer Room AC Units 10-15kW For Small Monitoring Room

Precision Computer Room AC Units 10-15kW For Small Monitoring Room

Structure & Components

Precision Computer Room AC Units 10-15kW For Small Monitoring Room

Comprossor

• The compressor has strong ability to withstand impurities and liquid shock
• Powerful built-in protection functions, including built-in motor disconnection protection, built-in pressure relief valve, built-in exhaust temperature protection, built-in anti-stop reverse stop valve, etc.

Fan
• Backward centrifugal fan, low noise
• High efficient, improve the energy efficiency ratio
• The air volume is more than 35% higher than the air volume of the comfort air conditioner with the same cooling capacity

Humidifier
• Direct electrode humidifier
• Fuzzy logic control humidification program
• Removable for cleaning
• Microcomputer-controlled automatic flushing cycle process
• Low noise water supply solenoid valve to ensure quietness
• Automatic failure prevention during operation

Product Specification

Model M04 M06 M08 M13 M16 M20
Power Supply 220V1Ph-50Hz 380V3Ph-50Hz
Air discharge Up Front/Down
Technical Data Sheet
AC Fan Total cooling capacity-KW 4.2 6.4 7.5 12.5 16.8 20.2
Sensible cooling capacity-KW 3.9 5.8 6.9 11.3 15.3 18.3
Unit FLA-A(heating, humidifying type) 20.0 25.0 16.8 22.0 23.5 28.6
Compressor Quantity 1
Fan Quantity 1
Air Volume-m3/h 1600 1900 2300 3600 5100 6500
Heater Capacity-KW 3.0 3.0 6.0 6.0 6.0 6.0
Humidification-kg/h 3 3 3 3 6 6
Power of humidifier-KW 2.3 2.3 2.3 2.3 4.5 4.5
Outdoor Condenser
Model SCA020 SCA020 SCA030 SCA030 SCA050 SCA050
Standard unit operating temperature range-℃ -15-45℃
Low Temperature Components Operating Temperature Range-℃ -40-45℃

Certificates

Precision Computer Room AC Units 10-15kW For Small Monitoring Room

Factory Details

Precision Computer Room AC Units 10-15kW For Small Monitoring Room

Packing & Delivery

Precision Computer Room AC Units 10-15kW For Small Monitoring Room

Cases

Precision Computer Room AC Units 10-15kW For Small Monitoring Room

Inquiry Cart 0