Single Row Cold Aisle Containment Integrated Data Center Module

Ask Latest Price
Video Channel
Brand Name :COOLNET
Model Number :R16
Certification :CE,ISO
Place of Origin :CHINA
MOQ :1set
Price :1800-30000USD
Payment Terms :T/T, L/C
Supply Ability :300 PCS PER MONTG
Delivery Time :10-25 working days
Packaging Details :Packed in plywooden case, standard export package
Product :Single Row Cold Aisle Containment
Mounting :Floor Standing
Power Supply :380/400 VAC,230 VAC,220V
Application :large-scale data centers in IDC, large enterprises, financial centers, governments,
Rack numbers :16pcs
Rack Power :3KW
UPS Capacity :3*30KVA
Cooling Unit :Row Based Air Conditioning
Cooling Capacity :4*20KW
Dimension :14400mm(L)*2400mm(W)*2300mm(H), 2600mm with skylight turning
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Integrated Data Center Module Single Row Cold Aisle Containment With In Row Air Conditioning

Product Introduction

IDM (Integrated Data Center Module) adopts an integrated integrated solution. The product module integrates the cabinet system, power supply and distribution system, refrigeration system, monitoring system and integrated wiring system. With high-density modularization, high reliability and safety, rapid and flexible deployment, simple and low-consumption, perfect monitoring and other characteristics, it is a new generation of integrated medium-sized data center solutions.

Feature & Benefits

Single Row Cold Aisle Containment Integrated Data Center Module

Single Row Cold Aisle Containment Integrated Data Center Module

Single Row Cold Aisle Containment Integrated Data Center Module

Advantages

Single Row Cold Aisle Containment Integrated Data Center Module

1. The only complete set of independent research and development products in the industry.

2. Modular UPS, single module 10K-40K optional, flexible configuration.

3. Energy-saving row-level air conditioner, fluorine pump natural cooling system saves more than 50% energy.

4. Built-in smart display touch screen, support information local + remote monitoring.

5. All products have uniform appearance and good compatibility.

Applicable Sence

Single module Solution : It is suitable for small and medium data centers with power consumption less than 180KW and an area of less than 100 square meters. For data center needs of small and medium enterprises and branch offices of large enterprises.

Multi-module solution: Through the flexible arrangement of multiple modules, a large-scale data center can be constructed. For the needs of large-scale data centers in IDC, large enterprises, financial centers, governments, military, supercomputer centers, education, medical and other industries.

Air-cooled module solution: Applicable to various medium and small data centers, such as: operator data centers, data centers of various industries (finance, government, energy, medical, etc.) and other enterprise-level data centers

Chilled water module: It is suitable for all kinds of large and medium data centers with chilled water hosts, such as: Internet data centers, operator data centers, data centers in various industries (finance, government, energy, medical, etc.) and other enterprise-level data centers.

Single Row Cold Aisle Containment Integrated Data Center Module

Main Basic Unit Introduction

Single Row Cold Aisle Containment Integrated Data Center Module

Rack

Multi-functional cabinet developed for large, medium and small data centers. It has the advantages of sturdy structure, strong load-bearing capacity, noble and elegant and assembling structure design. Cabinet integrated three major solutions (power management solution, cable management solution, heat dissipation management solution), It can be used as a modular equipment installation infrastructure, cabinet-type power distribution cabinet, rackmounted battery box, Cabinet integrated user equipment, power distribution, UPS, battery box, and monitoring system, greatly save the equipment area in the computer room.

Aisle Containment -Modular design
Adopting modular unit design concept, each unit can be installed and disassembled independently, and can be closely connected with adjacent units, which is convenient for disassembly and assembly; at the same time, it is also suitable for maintenance and management of other equipment on the channel.
Good sealing
All unit modules in the hot and cold aisle system are connected precisely, and the parts are sealed with good sealing tops or sponge strips, which not only maintains the aesthetics, but also prevents the leakage of cold air in the cold aisle.
Good light transmission
The system is composed of toughened glass with strong light transmittance

Power Supply- Modular UPS

According to the power supply requirements of large and medium-sized data centers, a modular UPS solution has been introduced, which can be flexibly configured with 80-300kVA modular UPS according to the customer's system power supply requirements. The module adopts advanced high-frequency switching technology, fully digital DSP control technology and the world’s leading active PFC and LLC topologies to achieve high input power factor, accurate output current sharing performance, and reliable monitoring and management system. The equipment provides safe, reliable and pure AC power.

Cooling System - In Row Air Conditioning Unit

Inverter In Row air conditioners are tailor-made high-density cabinets, adopts advanced frequency conversion technology and uses the environmentally friendly refrigerant R410A. The output cooling capacity is adjusted in real time according to the change of the detected load, to avoid frequent start and stop, and to ensure the temperature of the computer room environment.
Compared with fixed frequency air conditioners, the annual energy saving rate of variable frequency inter-train air conditioners can reach 29%

Monitoring System

The monitoring system system has the characteristics of simple configuration, strong access, and high reliability. It can manage all power, environment, and cooling in data center, integrate mainstream brand access control, video and other security systems, through distributed collection, high concurrent processing capabilities Meet the needs of networked monitoring and management of multiple computer rooms, allowing data center operation and maintenance personnel to control the operation safety of the computer room in real time.

Single Row Cold Aisle Containment Integrated Data Center Module

Single Row Cold Aisle Containment Integrated Data Center Module

Air Supply Method

Single Row Cold Aisle Containment Integrated Data Center Module

Technical Specification

Equipment System

Item

Parameter

System

Dimension

1200mm enclosed cold/hot aisle dual-row cabinets

1200mm enclosed cold/hot aisle Single-row cabinets

Rack Quantity

Dual Row Racks:≤48,Single Row Racks:≤24

Rack

Dimensions

600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U

Protection Class

IP20

Enclosed Aisle

Skylight

300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight

Power Supply and Distribution

Dimension

600mm(W)*1200mm(D)*2000mm(H)

UPS Power Supply

380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99

Battery

40AH~240AH/12V Valve Regulated Lead Acid Battery

Cooling

Indoor Unit Size

300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H)

Cooling Capacity

Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW

Power Supply

3Phase 380VAC,50Hz

Air Supply

Front Supply

Type

Enclosed Hot/Cold Aisle

Protection

IP20

Monitoring System

Monitoring

Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm

Equipment monitoring

Power supply, battery, power distribution, air conditioning

Certificates

Single Row Cold Aisle Containment Integrated Data Center Module

Factory Details

Single Row Cold Aisle Containment Integrated Data Center Module

Parking & Delivery

Single Row Cold Aisle Containment Integrated Data Center Module

Cases

Single Row Cold Aisle Containment Integrated Data Center Module

Inquiry Cart 0