ISO9001 Data Center Server Rack Mount Air Conditioner

Contact Now
Hefei Coolnet power Co., ltd
Visit Website
City:hefei
Province/State:anhui
Country/Region:china
Contact Person:Janet Si
Contact Now

ISO9001 Data Center Server Rack Mount Air Conditioner

Ask Latest Price
Video Channel
Brand Name :Coolnet
Model Number :CI05,09
Certification :CE/ISO9001
Place of Origin :China
MOQ :1
Price :$500.00-5000.00/set
Payment Terms :T/T
Supply Ability :1000-5000/set/month
Delivery Time :4W
Packaging Details :WOODED
Cooling Capacity :3.5KW-9KW
Color :Black/Grey white/other custom colors
Mounting :Rack mountnting
Power :1N-220V-50Hz,110v/50hz/60hz
Air Flow :750-1100M3/H
Application :cabinet/ intelligent project and medium & small sized enterprise
Height :5U,9U
Type :Split
Voltage :220V, 380V
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

In-Rack Cooling In Server Rooms & Data Centers For Server Cabinet Cooling

Product Introduction

In-Rack is the most precise cooling available, as the rack and the air conditioner operate in a closed relationship with one another. Cold air has no choice but to pass through the servers; hot air has no choice but to pass through the heat exchanger. In-Rack cooling provides a computing environment-a microclimate-that is thermally neutral to the rest of the room.

The In-Rack split type air conditioner power supply is 220VAC, focus on mini-ICT room heat management, which widely used for small scade IT equipment cooling for middle size of enterprises etc.

Feature & Benefits

ISO9001 Data Center Server Rack Mount Air Conditioner

ISO9001 Data Center Server Rack Mount Air Conditioner

Scope of Application

ISO9001 Data Center Server Rack Mount Air Conditioner
  • Micro Data C enter
  • Single row cabinet
  • Modular Computer Rooms
  • Medium and high heat density computer room
  • Modular Data Center
  • IT Rack for Blade Servers

Air Supply Method
ISO9001 Data Center Server Rack Mount Air Conditioner
Product Advantages

Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function;
* Strict process control and famous brand components to ensure high quality and reliability
of this product;
* Fit for harsh condition (T3), R134a refrigerant ;
* Multiple self-protection design , RS485 communication port (MODBUS-RTU protocol);
* LED display, all the settings can changed at the field;
* Built-in condensate water evaporating device;
* Dry contact alarm output, NO/NC optional;

ISO9001 Data Center Server Rack Mount Air Conditioner

Indoor Unit Parameters

Model-CJA 0003 0005 0007 0012
Phase/Function 1.5P,Single Phase 2P,Single Phase 3P,Single Phase 5P,Single Phase
Parameters
Cooling capacity kW 3.5 5 7.5 12.5
Sensible cooling capacity k W 3.5 5 7.5 12.5
Air volume m³/h 800 1150 1600 2300
Sensible heat ratio % 100 100 100 100
Heating kW (Option) 1 1 2 3
Maximum operating current A 15 15 25 34
Power Cord Cable Specifications mm 3×2.5 3×2.5 3×4 3×6
Indoor/outdoor unit shut-off valve
Refrigerant gas pipe φ mm 12.7 12.7 12.7 15.88
Refrigerant liquid pipe φ mm 9.52 9.52 9.52 9.52
Indoor unit structural parameters
Dimension:W×D×H mm 442×714×175 (4U)
442×714×218 (5U)
442×714×218 (5U) 442×714×351 (8U) 442×714×440 (10U)
Outdoor Unit
Type-CJT 3005 3005 3008 3013
Quantity 1 1 1 1
Note 1: Under standard conditions, the indoor dry bulb temperature is 37°C, the wet bulb temperature is 21°C, and the outdoor dry bulb temperature is 35°C;
Note 2: The above table is only part of the parameters, the specific configuration is subject to the actual purchase of the nameplate.

Outdoor Unit Parameters

Type- CJT 3005 3005 3008 3013
Power supply 220Vac/1Ph/50Hz
Installation Vertical
Speed mode Stepless speed regulation
Noise dBA 54 55 56 58
Rated current A 6 6 10 15
Power Cord Cable Specifications mm 4×1.5 4×1.5 4×2.5 4×4
Communication cable specificati mm (with shielding function) on 3×1 3×1 3×1 3×1
Structural parameters of outdoor unit
Dimension:W×D×H mm 840×285×610 840×285×610 880×360×800 930×390×1270

① The power cord of the outdoor unit must be connected from the indoor unit;

②The ex-factory unit is not equipped with a 4.3-inch touch screen, and needs to be purchased separately.