All-In-One Solution For Data Center Cooling System Container Integrated Solution With Precision Air Conditioning Unit
Product Introduction Coolnet modular data center can flexibly adopt the layout of double-row cabinets + cold/hot aisle or single-row cabinets + cold/hot aisle according to user site conditions. Under the two structural layouts, all subsystems such as cabinets, channels, power supply and distribution, refrigeration, security, environmental monitoring and management, and wiring can be integrated according to user needs, providing customers with new data of rapid deployment, high efficiency and energy saving, compact space, and flexible expansion Central solution.
Benefits | ![]() |
Features
![]() | Flexible Reliable Standardized Solution (Modular Design &Fast Deployment)
|
Advantage
High reliability standard module Modular data center adopts modularization, standardization and high reliability design, which makes the whole system highly stable. According to customer needs and actual conditions, N+1, N+X, 2N, etc. can be provided in the configuration of power supply and cooling core equipment. The design scheme is safe and reliable, and meets the standards of various levels from Tier3 to Tier4.
Rapid deployment, greatly shortening the construction period The micro-module data center improves the efficiency of planning and design, and can reasonably configure the system architecture according to IT business needs, such as the arrangement of the cabinets of the module units, the selected power supply and distribution equipment, cooling solutions, monitoring systems, etc.; Fast delivery, standardized components, reduce on-site assembly workload, and speed up installation; micro-modules can be assembled and pre-tested in the factory, which ensures the debugging speed and reliability of the system; modular design, combined with infrastructure + IT equipment All-in-one delivery reduces data center deployment cycles to weeks.
Green energy saving Data center power usage costs currently account for the largest portion of lifetime TCO. Modular data centers realize on-demand power supply and cooling of IT equipment, so that the capacity of the power supply and cooling system is more matched with the load demand, thereby improving work efficiency and reducing over-provisioning. The micro-module power conversion rate is as high as 95%. Due to the use of standardized interfaces and micro-module architecture, it can greatly save power and achieve system energy saving. The modular data center adopts closed and isolated cold aisles, so that the hot and cold air flows do not interfere with each other, which avoids the heat island effect caused by the crosstalk of the air flow, and avoids the loss of air volume and cooling capacity. At the same time, the use of inter-column air conditioners and the design of the near heat source of the refrigeration equipment improve the cooling efficiency, solve the problem of local hot spots, and reduce the operating cost of the data center. | ![]() |
Technical Specification
Equipment System | Item | Parameter |
System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets |
1200mm enclosed cold/hot aisle Single-row cabinets | ||
Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | |
Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U |
Protection Class | IP20 | |
Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight |
Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) |
UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | |
Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | |
Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) |
Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | |
Power Supply | 3Phase 380VAC,50Hz | |
Air Supply | Front Supply | |
Type | Enclosed Hot/Cold Aisle | |
Protection | IP20 | |
Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control, camera, water leakage alarm |
Equipment monitoring | Power supply, battery, power distribution, air conditioning |