Integrated Micro Data Center Modular Rack Data Center for Small Enterprises

Ask Latest Price
Video Channel
Brand Name :COOLNET
Model Number :EC20
Certification :CE ISO
Place of Origin :CHINA
MOQ :1Unit
Price :USD3,000-10,000/Unit
Payment Terms :L/C, T/T
Supply Ability :1000 Unit PER MONTH
Delivery Time :20-40 days
Packaging Details :Standard export package
Product name :Cabinet System
Refrigerant :R410A
Voltage :380v/220v,110-220v/50-60Hz,220V/50Hz
Cooling :DC Inverter Rack Mounted Precision Air Conditioner
UPS System :Online ,Rack Mounted Type
Application :a Small enterprises Branches and networks of large enterprises, government, education, Healthcare Edge Data Center
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Integrated Micro Data Center Modular Rack Data Center for Small Enterprises

Product Introduction

Coolnet Cabinet Data Center is an integrated cabinet which contains cooling system, power system, monitoring system and rack system, etc.. There are more and more micro data centers, and it has been facing the dilemma that it is difficult to unify the planning, construction and operation management. The integrated cabinet deeply integrates data center infrastructure products, including multiple subsystems such aS UPS, power distribution, refrigeration, cabinets, and fi re protection, and i m plements overa 11 management of the entire system through the monitoring system.

Integrated Micro Data Center Modular Rack Data Center for Small Enterprises

Advantages

Integrated Micro Data Center Modular Rack Data Center for Small Enterprises

Efficiency

  • Inverter compressor, matching the load size, reducing the energy consumption of the whole machine.
  • The cold and hot aisles at the front and rear of the cabinet are closed to improve the cooling efficiency of the air conditioner.

Stable and Reliable

  • Emergency fen as emergency cooling.
  • The power supply adopts 2N architecture.
  • The ultra-wide voltage input operates stably, and has power protection functions such as phase sequence detection.
  • Low temperature components or long connecting pipe components can be selected to ensure reliable operation.

Simpler

  • Integrated design, integrate UPS, battery, power distribution, air conditioning, monitoring, wiring, fire protection and other products in the cabinet, get rid of the traditional sub-item construction mode; modular design, unified interface of each component, fest on-site.

Technical Parameter

Series Conventional Air Conditioning Version
System Index EC20 ER02 ER03 ER05
Power supply and distribution UPS Capacity 3 KVA 6KVA 10KVA 20KVA
Power factor 0.8 0.8 0.8 0.9
Total power input 220V/40A 220V/63A 220V/125A 380V/125A
Height 4U 4U 4U 6U
Lightning protection C class
Others ATS Modle (optional)
Cabinet Recommended number of IT cabinets 1 2 3 5
Available space 28U 33U+42U 29U+2*42U 30U+4*42U
Number of PDUs in a single rack T8bitlOA T12bitlOA T(12bitlOA+4bitl6A)
Closed aisle Fully enclosed cold and hot aisle
Ergency ventilation Fan-type emergency ventilation system, support maximum 5KW heat dissipation, automatic start and stop
IT space expansion Standard IT cabinet with 42U usablespace (optional)
Refrigiration Type Rack mount In row In row In row
Cooling Capacity (KW) 3.5 7.5 12.5 2*12.5
Sensible heat ratio 1
System Compression system +EC fan
Monitoring Monitoring volume UPS,Power distribution,AC,Water leakagexTemperature & Humidity,Smoke,Door sensor
Function Data collection and storage, alarm management, energy consumption analysis, remote access, sound andlight alarm (optional), SMS alarm (optional), APP (optional)
Display 10-inch Touch screen
Fire Heptafluoropropane 1URack-mounted gas fire extinguishing system (optional)
Battery Standard number of batteries 8 16 16 20
Backup power for 15 minutes 2UBattery Pack 3UBattery Pack 6UBattery Pack
Backup power for 40 minutes External 20 100A/12V
Backup power for 90 minutes
Longer time delay Can be replaced with high-capacity batteries or increase the number of battery packs (not more than 4)
Size WD*H-mm 600*1200*2000 150,012,002,000 2100*1200*2000 3600*1200,2000
Environment Environment temperature 0~45°C
Environment humidity Relative humidity 0-95%, no condensation
Altitude <1000m,The excess part is derated according to relevant standards