ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

Ask Latest Price
Video Channel
Brand Name :Coolnet
Model Number :CYAT50
Certification :CE/ISO9001
Place of Origin :China
MOQ :1
Payment Terms :T/T
Delivery Time :4W
Packaging Details :WOODED
Cooling capacity :50kw
Condition :New
Mounting :Floor Standing
Type :precision air conditioning unit(chilled water) 3ton 5ton 10ton
After-sales service provided :Engineers available to service machinery overseas
Product name :Precision Air Conditioning
Precision Air Conditioning :R22(R407C/R410A)
Application :Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity
Color :Black/Grey white/other custom colors
Fan type :Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan
Power :3N-380V-50Hz,220v/50hz/60hz
Airflow :50000 m3/h
Voltage :380v/220v,220V/380V,380V/415V
Compressor :Scroll compressor
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Floor Standing Data Center PAC Server Room Precision Air Conditioner

Product Introduction

Precision air conditioning units

1. Maintaining a constant temperature, purity and humidity of air is essential for ensuring a stable environment for critical electronic and computer equipment.

2. Unlike comfort air conditioning, close control systems must operate constantly 24/7 requiring high reliability and minimal power consumption.

3. Quiet, compact and energy efficient equipment that can be configured to needed requirements.

Benefits

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

Advantages

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

1. High quality control component.

2. Efficient evaporator made from advanced technology and with larger heat exchange area.

3. Danfoss brand quality expansion valve.

4. Internationally advanced electrode steam humidification system.

5. Unique frame design guarantees the cabinet safety under any transport condition and operating environment.

6. G4 level air filter to guarantee the server room air purity.

7. Copeland hermetic scroll compressor.

8. Standard configuration with speed adjustable centrifugal fan. EC fan is optional.

9. Highly efficient PTC electrical heater.

10. Anti-corrosion alloy condenser.

Applications

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber
ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

Technical Features

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

High reliability

Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition.

All-day running design can guarantee the main equipment safe operation.

All parts had passed severe test and confirmed stable and reliable before delivery.

High energy efficiency

Sensible heat ratio is up to 91%.

Compressor energy efficiency ratio is over 3.1, and chilled water

cooled unit’s cooling energy efficiency is larger than 25.

The optimal and high efficiency compressor and fans.

“W/M” type evaporator with super large heat exchange area.

Independent air duct design can reduce air resistance significantly and minimize fans power.

Variable frequency design on ODU is more efficient and has longer

working life.

Advanced control logic can effectively avoid competitive running

and output cooling capacity according to actual cooling capacity

demand.

Easy maintenance

Front panel maintenance: All maintenance work can be operated from front panel.

Air filter with metal frame: Cleanable repeatedly, low maintenance cost

Self-cleaning humidifier: lower maintenance work

Modular design with least spare parts

Pressure difference monitoring for air filters can detect whether

air filters was blocked or not.

Multiple types

Wide capacity range:

air cooled type(5kW~120kW),Water cooled type(5-120KW),chilled water cooled type(30kW~200kW).

Multiple cooling mode:

air cooled, water cooled, glycol cooled, chilled water cooled(with single/dual coil), air cooled & chilled water cooled, air cooled & free cooling, Freon pump free cooling.

Multiple air supplying modes:

cap tuyere mode, air duct mode, floorboard mode.

Multiple refrigerant types: R410A, R407C, R22.

Wide ambient air temperature rang:

standard range(-20℃~50℃),low temperature range(-40℃~50℃).

Technical Parameters

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model 2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

Certificates

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

Factory Details

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

Packing & Delivery

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

Case

ISO9001 Floor Standing Data Center Server Room Air Cooling Unit

Inquiry Cart 0