Technological Room Precision Air Conditioning Units , CRAC Air Conditioning Unit

Ask Latest Price
Video Channel
Brand Name :Coolent
Model Number :CYAT40D/U
Certification :ISO/CE
Place of Origin :China
MOQ :1
Price :to be Negotiated
Payment Terms :T/T
Supply Ability :1000/Month
Delivery Time :4W
Packaging Details :WOODEN
cooling capacity :70KW
Mounting :Floor Standing
Condition :New
Type :precision air conditioning unit( air cooled )
After-sales service provided :Engineers available to service machinery overseas
Operating voltage :380/400 VAC,230 VAC,220V
Warranty :1 Year
Product name :CRAC Cooling unit
Refrigerant :R22(R407C/R410A)
Application :Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity
Color :Black/Grey white/other custom colors
Power :3N-380V-50Hz,220v/50hz/60hz
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Technological Room Applications Data Center CRAC Units

Product Introduction

Precision air conditioning controls the ambient environment by providing constant temperature and humidity conditions to costly and sensitive sophisticated electronic equipments throughout the year. This is in contrast to normal air conditioning which provides only the cooling comfort to people sitting in a room.

Benefits

Technological Room Precision Air Conditioning Units , CRAC Air Conditioning Unit

Technological Room Precision Air Conditioning Units , CRAC Air Conditioning Unit

Applications

Technological Room Precision Air Conditioning Units , CRAC Air Conditioning Unit
  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

Technical Features

Technological Room Precision Air Conditioning Units , CRAC Air Conditioning Unit

High reliability

Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition.

All-day running design can guarantee the main equipment safe operation.

All parts had passed severe test and confirmed stable and reliable before delivery.

High energy efficiency

Sensible heat ratio is up to 91%.

Compressor energy efficiency ratio is over 3.1, and chilled water

cooled unit’s cooling energy efficiency is larger than 25.

The optimal and high efficiency compressor and fans.

“W/M” type evaporator with super large heat exchange area.

Independent air duct design can reduce air resistance significantly and minimize fans power.

Variable frequency design on ODU is more efficient and has longer

working life.

Advanced control logic can effectively avoid competitive running

and output cooling capacity according to actual cooling capacity

demand.

Easy maintenance

Front panel maintenance: All maintenance work can be operated from front panel.

Air filter with metal frame: Cleanable repeatedly, low maintenance cost

Self-cleaning humidifier: lower maintenance work

Modular design with least spare parts

Pressure difference monitoring for air filters can detect whether

air filters was blocked or not.

Multiple types

Wide capacity range:

air cooled type(5kW~120kW),Water cooled type(5-120KW),chilled water cooled type(30kW~200kW).

Multiple cooling mode:

air cooled, water cooled, glycol cooled, chilled water cooled(with single/dual coil), air cooled & chilled water cooled, air cooled & free cooling, Freon pump free cooling.

Multiple air supplying modes:

cap tuyere mode, air duct mode, floorboard mode.

Multiple refrigerant types: R410A, R407C, R22.

Wide ambient air temperature rang:

standard range(-20℃~50℃),low temperature range(-40℃~50℃).

Technical Parameters

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model 2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

Certificates

Technological Room Precision Air Conditioning Units , CRAC Air Conditioning Unit

Factory Details

Technological Room Precision Air Conditioning Units , CRAC Air Conditioning Unit

Packing & Delivery

Technological Room Precision Air Conditioning Units , CRAC Air Conditioning Unit

Case

Technological Room Precision Air Conditioning Units , CRAC Air Conditioning Unit

Inquiry Cart 0